Lenovo ThinkServer RD650 User Manual

Page 116

Advertising
background image

5. Loosen the two screws and grasp the AnyRAID adapter or the pass-through board by its edges and

carefully pull it out.

Note: The AnyRAID adapter or the pass-through board might fit tightly into the slots. If necessary,
alternate moving each side of the AnyRAID adapter or the pass-through board a small and equal
amount until it is removed from the slots.

Figure 75. Removing the AnyRAID adapter or the pass-through board

6. Touch the static-protective package that contains the new AnyRAID adapter or the pass-through board

to any unpainted surface on the outside of the server. Then, take the new AnyRAID adapter or the
pass-through board out of the package.

Note: Carefully handle the AnyRAID adapter or the pass-through board by its edges.

7. Position the new AnyRAID adapter or the pass-through board near the backplane. Then, carefully

press the AnyRAID adapter or the pass-through board straight into the AnyRAID adapter slots until
it is securely seated.

Figure 76. Installing the AnyRAID adapter or the pass-through board

102

ThinkServer RD650 User Guide and Hardware Maintenance Manual