1 installation requirements – Konica Minolta KIP 2100 Scanner User Manual

Page 7

Advertising
background image

Chapter 1 Basic Functions

1-2

1. 1

Installation Requirements


The following conditions have to be satisfied when installing the KIP 2100 Scanner.

1. Satisfy the following input power condition.

Voltage

From 100V to 240V plus / minus 10%

Current

6A or higher

Frequency

50 or 60Hz.


KIP 2100 can be supplied with any voltage between 100V and 240V (plus / minus 10%). If the
voltage is within this range, please connect to the outlet simply. (No setting has to be
changed.)

2. Make sure to connect the power plug to the outlet that is provided with a Ground Terminal.

3. To completely disconnect the equipment from the power source, please draw the power plug
from the outlet. The outlet must be easily accessible near the equipment.

4. The temperature must be within the range from 10 to 32.5 degrees centigrade (50-90 F) & the
humidity must be from 20% to 80%.

5. Keep the equipment away from fire, dust and direct sunlight.
If it is impossible to avoid the direct sunlight, please pull the shades to block the sunlight.

6. The floor must be enough strong to withstand machine’s weight (About 68kg or 150lbs).

7. Keep enough space around the machine.
(The following values are the least requirements. Please keep a wider space if possible.)



















160cm or 63”

60cm

24”

60cm

24”

100cm or 40”
(200cm for 0.12mm or
thicker original)

(Front side)

(Rear side)

KIP 2100

Advertising