7 Specifications


Gases Detected ......................... Detects and measures, depending on instrument’s part number:

• CFCs, HCFCs, HFCs and Halogens
R11, R12, R21, R22, R23, R113, R114, R123, R124, R125, R134a, R227,
R236fa, R245fa, R401A, R402A, R402b, R404A, R407A, R407C, R408A,
R409A, R410A, R422a, R422d, R427a, R500, R502, R503, R507, R508B, HFP,
H1211, H1301, H2402, N1230, FA188, FC72

R600a

SF

6

Detection Method....................... Infrared

Measurement Units.................... oz/yr, g/yr, mL/s, PaM

3

/s, ppm

Measurement Range ................. 0.03 to 5.00 oz/yr

0.85 to 142 g/yr
0.08 x 10

–4

to 100 x 10

–4

mL/s

0.08 x 10

–5

to 100 x 10

–5

PaM

3

/s

0 to 1,000 ppm

Operating Modes ....................... Search: detects presence and location of gas leaks

Measure: calculates and displays leak rate

Response Time.......................... Up to 2.5 seconds (dependent on probe-hose length)

Sensitivity................................... 0.03 oz/yr (0.9 g/yr) all gases

Resolution .................................. 0.1 leak units

Accuracy:

Leak

Rate.............................. ±15% of the reading (certified leak source uncertainty)

±1% of reading (instrument uncertainty)

PPM ...................................... ±10% of reading (can be improved to ±1% if recalibrated using a known

concentration of refrigerant gas)

Temperature Drift....................... ±0.3% of reading per °C

Calibration.................................. Internal: calibration performed using the unit’s built-in leak source

External: calibration performed using a customer supplied leak
source of a known gas type and leak rate

Relays ........................................ Four SPDT relays (rated 2 A at 250 VAC – inductive and 5 A at 250 VAC –

resistive)), each programmable to energize under 11 different operating
conditions

Audio Speaker ........................... Audible indication of leak level

AC Power................................... 100 to 240 VAC, 50/60 Hz

Battery........................................ 16V

Power Consumption .................. 15 Watts

Warm-Up Time........................... 2 minutes (30 minutes to meet published specifications)

Operating Temperature ............. 32 to 122 °F (0 to 50 °C)

Storage Temperature.................

4 to 122 °F (20 to 50 °C)

Ambient Humidity....................... 5 to 90% RH, non-condensing

Dimensions ................................ 4 x 10.75 x 15.5 in.

(101.6 x 273.1 x 393.7 mm)

Weight........................................ 18 lb (8.2 kg)