Troubleshooting

Table 7.2 BIOS Boot Error Messages (Continued)

Message

Problem

Suggested Solution

X Logical Drives
Degraded

x number of logical
drives signed on in a
degraded state.

Make sure all physical
drives are properly
connected and are powered
on.

Run

MegaRAID Manager

to find if any physical
drives are not responding.
Reconnect, replace, or
rebuild any drive that is not
responding.

1 Logical Drive
Degraded

A logical drive signed on
in a degraded state.

Make sure all physical
drives are properly
connected and are powered
on.

Run

MegaRAID Manager

to find out if any physical
drives are not responding.
Reconnect, replace, or
rebuild any drive that is not
responding.

The following SCSI IDs
are not responding:

Channel x:a.b.c

The physical drives with
SCSI IDs a, b, and c are
not responding on SCSI
channel x.

Make sure the physical
drives are properly
connected and are powered
on.

Advertising