Dos aspi driver error messages – Toshiba Magnia 560S User Manual

Page 102

Advertising
background image

Troubleshooting

84

Troubleshooting

DOS ASPI Driver Error Messages

Table 7.4 lists the DOS® ASPI® driver error messages, and actions used to correct the
problems.

Table 7.4 DOS ASPI Driver Error Messages

Message

Corrective Action

Toshiba ASPI Manager
has NOT been loaded.

The ASPI manager is not loaded. One of the failure
codes listed below displays next.

Controller setup FAILED
error code=[0xab]

Correct the condition that caused the failure. The
failure codes are:

0x40

No MegaRAID adapters found

0x80

Timed out waiting for interrupt to be posted

0x81

Timed out waiting for MegaRAID
Response command.

0x82

Invalid command completion count.

0x83

Invalid completion status received.

0x84

Invalid command ID received.

0x85

No MegaRAID 320-1 adapters found or no
PCI BIOS support.

0x90

Unknown Setup completion error

No non-disk devices were
located

The driver did not find any non-hard drive devices
during scanning. A SCSI device that is not a hard disk
drive, such as a tape drive or CD-ROM drive, must be
attached to this SCSI channel. The SCSI ID must be
unique for each adapter and cannot be SCSI ID 0. The
supported SCSI IDs are 1, 2, 3, 4, 5, and 6.

'ERROR: VDS support is
*INACTIVE* for RAID
Controller Kit-G logical
drives

The /h option is appended to driver in CONFIG.SYS or
this driver is used with a BIOS that is earlier than
v1.10, or no logical drives are configured.

Advertising