Other bios error messages – Toshiba Magnia 560S User Manual

Page 101

Advertising
background image

Troubleshooting

Troubleshooting

83

Other BIOS Error Messages

Table 7.3 lists other BIOS error messages, problems, and suggested solutions.

Table 7.3 Other BIOS Error Messages

Message

Problem

Suggested Solution

Following SCSI
disk not found
and no empty slot
available for
mapping it

The physical disk roaming
feature did not find the
physical disk with the
displayed SCSI ID. No slot
is available to map the
physical drive. RAID
Controller Kit-G cannot
resolve the physical drives
into the current
configuration.

Reconfigure the array.

Following SCSI
IDs have the same
data y, z

Channel x: a, b, c

The physical drive roaming
feature found the same data
on two or more physical
drive on channel x with
SCSI IDs a, b, and c. RAID
Controller Kit-G cannot
determine the drive that has
the duplicate information.

Remove the drive or drives
that should not be used.

Unresolved
configuration
mismatch
between disks
and NVRAM on
the adapter

The configuration stored in
the RAID Controller Kit-G
NVRAM does not match the
configuration stored on the
drives.

Press a key to run

MegaRAID

Manager

.

Choose View/Add
Configuration from the
Configure menu.

Use View/Add Configuration
to examine both the
configuration in NVRAM and
the configuration stored on the
disk drives. Resolve the
problem by selecting one of
the configurations.

Advertising
This manual is related to the following products: