Toshiba Magnia 3030 User Manual
Page 77

Installing and Removing Hardware
Cooling Fan
59
2 For the EPS model, unplug the power cable from the AC outlet.
3 For the EPS-R model, turn off the DC operate switch on the back of the
server first and then unplug the power cable from the AC outlet.
NOTE: If the cooling fan is removed as the server is turned on, the service life
of the fan and server may be shortened.
4 Remove the covers from the server.
See “Removing and replacing the server panels” on page 24.
5 Disconnect the cables from the basic fan module or redundant fan module
that is the object of removing.
Disconnecting the suction fan cable
Disconnecting the exhaust fan cable
6 For removing the suction fan module, remove the screw and draw out the
basic or redundant fan module.
Removing the suction fan module
7 For removing the redundant exhaust fan module, remove the screws from
the fan duct and then draw out the redundant exhaust fan module.