Toshiba Magnia 3030 User Manual
Page 78

Installing and Removing Hardware
Cooling Fan
60
Removing the redundant exhaust fan module
8 For removing the basic exhaust fan module, remove the screws fixing the
fan duct and remove the basic exhaust fan module together with the fan
duct.
The basic exhaust fan module is directly fitted to the fan duct.
Removing the exhaust fan duct
9 If it is intended to leave the redundant fan module as it is removed, fasten
the spacer with the screws to cover the vacant slot.
The server cannot be operated as a basic fan module is removed from it.
NOTE: If the system is started without the EPS-R cage or cooling fan of the
redundant configuration, the fault indicator lamp (
) blinks because the
SMC judges the status as a downgraded operation. If the server comes into
this status, it is needed to renew the data of the SMC board by means of the
“Sensor Data and LCD Setup Tool” floppy disk produced from the “Toshiba
Server Setup Tool”. The fan module to remove is limited to a redundant one.
See “Sensor Data and LCD Setup Tool” on page 146