Choosing the right teat for your baby, Troubleshooting guide – Philips AVENT Extractor de leche manual User Manual

Page 15

Advertising
background image

9

8

GB

GB

12. Choosing the right teat for your baby

AVENT Teats can be used on both the VIA Feeding System and

AVENT Feeding Bottle. AVENT Teats are clearly numbered on the
side to indicate flow rate.

1

3

2

4

0

m

+

6

m

+

1

m

+

3

m

+

3

m

+

1 hole

2 holes

3 holes

4 holes

1 slot

NEWBORN FLOW
EXTRA SOFT SILICONE TEAT
Ideal for newborns and breastfed
babies of all ages.

SLOW FLOW
EXTRA SOFT SILICONE TEAT
Ideal for newborns and breastfed
babies of all ages.

MEDIUM FLOW
SOFT SILICONE TEAT
For bottle fed babies at 3 months
of age and up.

FAST FLOW
SOFT SILICONE TEAT
Offers a faster flow for older babies.

VARIABLE FLOW
SOFT SILICONE TEAT – SLOT CUT
Provides an extra fast flow and
accommodates thicker liquids.
Flow rate can be varied by turning
the bottle to align the I, II or III markings
on the teat with baby’s nose.

13. Troubleshooting guide

Lack of suction


No milk being expressed


Pain in the breast area
when expressing

Milk is drawn up the
Let-down Massage Cushion


Cracking/discolouration of
pump parts


Lost or broken parts

Check that all the pump components have been
assembled correctly and that the white valve is the
right way up. Ensure that the diaphragm and Let-down
Massage Cushion are fitted securely to the pump body
and a perfect seal is created.

Ensure suction is created and the pump is correctly
assembled. Relax and try again, expression may improve
after practice. Please refer to the ‘Hints to help you
succeed’ section.

You may be pumping too hard. You do not need to use
all the suction the pump can generate. Try depressing
the handle halfway and remember the 2-3 second
pumping rhythm. Consult your health professional/
breastfeeding advisor.

Remove and refit the Let-down Massage Cushion
ensuring it is firmly attached and pushed far enough
down the funnel. Try leaning slightly forward.

Avoid contact with antibacterial or abrasive detergents/
cleaners as these can damage the plastic. Combinations
of detergents, cleaning products, sterilising solution,
softened water and temperature fluctuations may, under
certain circumstances, cause the plastic to crack. If this
occurs, do not use. Contact Philips AVENT Customer
Services for spare parts. The pump is dishwasher safe
but food colourings may discolour components.

Spare parts are available through Philips AVENT Customer
Services (see back cover for contact details).

If you are still experiencing problems, please contact Philips AVENT Customer
Services. (see back cover for contact details). Alternatively contact your
health professional/breastfeeding advisor.

Advertising