16. installing the operation panel, 17. connecting the ground wire, Caution – Brother LK3-B448E User Manual

Page 24

Advertising
background image

LK3-B448E MARK

II

/BA-16

17

3. Installation

3-16. Installing the operation panel

The operation panel can be installed to either the top or bottom of the work table.

3-17. Connecting the ground wire

CAUTION

Be sure to connect the ground. If the ground connection is not secure, you run the risk of receiving a
serious electric shock, and problems with correct operation may also occur.

1. Install the operation panel presser plate

q

to the top of the button feeder cover with the two screws

w

.

2. Insert the panel

e

into the operation panel presser plate

q

, and then secure it with the two screws

r

.

3. Insert the connector cord

t

into the control box through the hole at the side of the box. Refer to “3-13. Connecting

the cords” for details on connecting the cord.

Red

White

Black

Yellow/Green ....... Connect to ground

Connect to the power switch. However, the
black wire is insulated to the inside of the
box and is not used.

r

w

q

e

Advertising