Image files menu – Barco ULTRA REALITY 7000 User Manual

Page 73

Advertising
background image

10. Image files menu

Advanced edit

On

Comb filter

Off

Short

AGC hold interval

Long

Coarse

Sharpness

Fine

Image 10-8

video signal

video signal

frame blanking

HI

egalisation

Image 10-9

HI AGC Hold interval

The Comb filter is by default enabled.

The AGC hold interval is the time interval in which the AGC is inhibited (AGC hold = no update in video amplitude measurement),
the advanced parameter allows to choose a short or long hold interval.

A long AGC hold interval eliminates Macrovision

®

disturbances since the AGC is hold during a long interval, thus reducing the

probability to encounter a Macrovision

®

pulse.

Sharpness adjustment can be chosen to be coarse or fine.

It is recommended to use the default values.

Advanced Data settings

The advanced button enables the advanced settings for a data source.

Advanced edit

VCO range

PLL Cpmp

0

0

Clamp position

Clamp width

16

16

RGB
PR/Y/PB

Input format

HDTV-PR/Y/PB

Image 10-10

The VCO range setting determines the frequency range of the VCO (Voltage Controlled Oscillator).

The Cpmp (Charge pump current) sets the low pass filter current.

Both VCO range & Cpmp are set by the image file, changing these settings is only indicated in for special purposes.

The input format settings are used to "tell more" about the signals connected on the BNC’s, it completes the information in the source
selection menu.

It is recommended to use the default values.

R5976455 BARCO ULTRA REALITY 7000 30062003

69

Advertising