Page 17: Problem: water is dripping from the streamformers

Advertising
background image

17

Express® Lavatory System SS-Series

Installation - Obsolete

SS-2/AST/STD, SS-2/AST/JUV

Bradley Corporation • 215-1244 Rev. D; EN 08-805

4/24/08

PLASTIC DISK
269-664

Metering Air Valve Maintenance

Metering Air Valve Repair Kits and Parts List

Metering Air Valve Troubleshooting

Problem: Water is dripping from the streamformers

Cause: Debris on valve seat or orifices.

Solution: Clean and inspect the valve seat.

1. Remove screws and disassemble metering valve.

2. Clean the valve seat and inspect for deep gouges or scratches. Replace if necessary.

3. Remove all debris that may be clogging center hole of plastic diaphragm assembly.

4. Remove any debris clogging the off-center hole in the rubber diaphragm.

Metering Air Valve Troubleshooting continued . . .

REPAIR KIT
S73-054A

(Note: This repair
kit also includes
kit S65-110)

VALVE SEAT

117-036

LOWER

VALVE BODY

118-183

RUBBER DIAPHRAGM
269-665

STAINLESS
STEEL DISK
179-082

SPRING
135-053

CENTER HOLE

LOCKWASHER

142-002CR

SCREW

160-313

PARTS INCLUDED
IN KIT S65-110