Express® Lavatory System SS-Series

Installation - Obsolete

SS-2/AST/STD, SS-2/AST/JUV

Bradley Corporation • 215-1244 Rev. D; EN 08-805

4/24/08

Installation Instructions

Step 1: Rough in

Note: See Figure 1a below (for Standard Height) and Figure 1b on page 6 (for Juvenile Height)
when roughing in the Express®.

IMPORTANT: Flush the supply lines before making connections. Debris in supply

lines can cause the valves to malfunction.

IMPORTANT: Dimensions shown in Figure 1a are for Standard Height and in

Figure 1a for Juvenile Height.

1. Rough in 1/2" NPT hot and cold supply lines through wall at dimensions shown.

2. Rough in 1-1/2" NPT drain waste connection through wall at dimensions shown.
3. Install (6) 3/8" wall anchors with a minimum pull-out rating of 1,000 lbs. (supplied by

installer) at the locations shown in Figures 1a and 1b.

(MM)

32"

(813)

28-5/8"

(727)

25"

(635)

11-3/8"

(289)

(6) 3/8" WALL
ANCHORS WITH
MINIMUM PULLOUT
RATING OF 1,000
LBS.

23-1/2"

(597)

9-3/8"

(238)

2-3/4"

(70)

1"

(25)

23-1/2"

(597)

9-3/8"

(238)

1/2" NPT HOT AND
COLD SUPPLIES,
OR TEMPERED
SUPPLY - STUB
OUT 2" (50) FROM
WALL

FINISHED
FLOOR

CENTERLINE

15-1/4"

(387)

1-1/2" NPT DRAIN -

STUB OUT 2" (50)

FROM WALL

Figure 1a

Installation Instructions continue . . .

3"

(76)

SS-2/AST/STD Express® Lavatory System Dimensions

Standard Height Mounting