Express® Lavatory System SS-Series
SS-2/AST/STD, SS-2/AST/JUV

Installation - Obsolete

4/24/08

Bradley Corporation • 215-1244 Rev. D; EN 08-805

Pre-Installation Information

Barrier-free and ADA compliant - standard height mounting

The SS-2/AST/STD Express® Lavatory System is compliant with Americans with Disabilities Act
(ADA). When mounted at 34" rim height, the Express® meets ADA, ANSI and UFAS require-
ments for barrier-free clearances, reaches and controls. Always check local codes and ordinances
for compliance.

Barrier-free and ADA compliant - juvenile height mounting

The SS-2/AST/JUV Express® Lavatory System is compliant with Americans with Disabilities Act
(ADA) Accessibility Guidelines for Buildings and Facilities: Building Elements Designed for
Children's Use; Final Rule.

Pushbutton and air valve

Each sprayhead is controlled by a pushbutton air valve, enabling each user to activate a single flow
of water. Air valves use 0.5 gpm for a ten-second duration, meeting the ANSI/ASHRAE/IES
90A-1980 Standard.

Supplies required for installation:

• (6) 3/8" wall anchors, bolts and washers to mount frame and bowl to wall

(minimum pull-out rating of 1,000 lbs.)

• 1/2" NPT hot and cold supply piping
• 1-1/2" NPT drain piping