Installation instructions continued – Bradley Smoker EXPRESS SS-2/AST/JUV User Manual

Page 9

Advertising
background image

9

Express® Lavatory System SS-Series

Installation - Obsolete

SS-2/AST/STD, SS-2/AST/JUV

Bradley Corporation • 215-1244 Rev. D; EN 08-805

4/24/08

Installation Instructions continued . . .

Step 4: Connecting supply and drain

1. FOR HOT AND COLD SUPPLY: Connect the flexible hoses installed to the Vernatherm™

Mixing Valve to the hot and cold water supply piping from the wall (see Figure 6a).

Note: The red marking on Vernatherm™ Mixing Valve indicates hot water supply inlet.

FOR SINGLE TEMPERED SUPPLY: Attach the stop/strainer/check valve to the 1/2" tempered
supply line. Connect the flexible hose to the stop/strainer/check valve and air valve manifold
(see Figure 6b).

2. Install the drain plug in the hole in the bottom of the bowl (see Figure 7).

3. Beneath the bowl, install the 1/4" rubber washer onto the drain plug, and thread the tailpiece

to the drain plug.

4. Assemble the P-trap by connecting the 1-1/2" tubular pipe to the tailpiece and to the 1-1/2"

drain pipe stubbed out of the wall.

5. Install the strainer on the drain plug opening inside the bowl, and push the strainer firmly

into place. Secure the strainer to the drain with the screw provideed.

Figure 7

Figure 6b

FLEXIBLE

SUPPLY

HOSE

CONNECT TO
TEMPERED
WATER SUPPLY

Figure 6a

FLEXIBLE

SUPPLY

HOSE

VERNATHERM™

THERMOSTATIC

MIXING VALVE

FLEXIBLE

SUPPLY

HOSE

CONNECT TO

1/2" NPT COLD

WATER SUPPLY

CONNECT TO
1/2" NPT HOT

WATER SUPPLY