19. Troubleshooting

19. TROUBLESHOOTING

An Administrator password has been installed for security reasons (worm and virus protection):

Password : Barco (case sensitive !)

FAQ table

This table gives a summary of possible errors, the aim of this section is to give general guidelines and tips for troubleshooting.

19.1 FAQ table

What to do when... ?

Symptom

Possible cause

Check

References

The projector is working
(operational mode) but Server
is not running

The Projector ON state
setting ( in the “iQ Pro
Server settings” menu)

The setting should be

“ON”

The projector is in standby mode
and the Server is not running

The Projector Standby
state setting ( in the “iQ Pro
Server settings” menu)

The setting should be
“ON”

No client/server communication
in case of a point to point
communication

IP address is not filled in
correctly

IP address

No client/server communication
over the LAN

Client configuration

Client configuration:
projector name

IT administrator

When using the DropZone, the iQ
Pro server does not accept calls
from client(s)

Netmeeting

TM

settings are

incorrect

Netmeeting

TM

settings

IT administrator

When using the DropZone it is
impossible to launch/store files

No access the shared
folder “Received”

check guest account
settings in Windows

TM

IT administrator

PC card is not working or influences
the good working of the SBC

incompatible PC card

Check if the PC card
driver is compatible with
Windows

TM

XP

IT administrator

R5976694 IQ PRO R500 01/02/2007