Pilot signal guidelines – Ransburg DynaFlow User Manual User Manual

Page 19

Advertising
background image

LN-9400-00.9

DynaFlow

TM

User Manual - Installation

15

Do not locate the Control Panel

near or adjacent to heat producing equip-

ment such as ovens, high wattage lamps,

steam pipes, etc.

C A U T I O N

!

1/4"

1/4"

Tubing Size

OD

Fluid Regulator

Type
MVR

DR1

Typical

Application

Two-component

Single-Component

15

15

Feet

Meters

4.6

4.6

Feet

Meters

50

100

15.3

30.5

Maximum

Length

Minimum

Length

PILOT SIGNAL GUIDELINES

Equipment Mounting

Use the mounting ears supplied to mount the

control or interface enclosure on a wall or build-

ing structure. The anchor system used must be

rated to support the specified weight of the en-

closure being mounted (see specifications, page

13). When properly mounted, the anchor system

shall be capable of withstanding 4 times the rated

weight without causing a hazardous condition.

The Control Enclosure must be lo-

cated in such a way that access to the On/

Off power switch and Stop switch is not

blocked.

The On/Off switch turns off AC power to the

PC and 24 VDC supply.

The Stop switch interrupts only the 24

VDC.

The AC power input FUSED DISCONNECT

must be located in an accessible area near

the Control Enclosure

W A R N I N G

!

If improperly located, certain electrical

equipment can become a source of ignition

and create a risk of fire or explosion.

The Control and Interface Enclosures must

be located outside of the Class 1, Division

1 and 2 hazardous locations which are de-

fined for spray finishing of flammable and/

or combustible materials. Definitions and

requirements for classified areas are found

in the National Electrical Code, NFPA-70,

Article 516 and the National Fire Protection

Association (NFPA-33).

W A R N I N G

!