User Manual - Maintenance

Interface Module Settings

Jumper

Description

Comments

E4

E5

E10

E2

E3

E6

E7

E8

E9

ROM size select.

1-2 = 256K, 27256 device

2-3 = 512K or 1024K, 27512 or

27010 devices

RS-232C/RS-485 select

RS-485 termination resistor

CAN Bus termination resistor

Circuit common to earth ground connec-

tion.

Selects 24 VDC source control or grounded

sink control for digital inputs

12-15.

2-3 = 24 VDC source

1-2 = grounded sink

Selects 24 VDC source control or grounded

sink control for digital inputs

8-11.

2-3 = 24 VDC source

1-2 = grounded sink

Selects 24 VDC source control or grounded

sink control for digital inputs 4-7.

2-3 = 24 VDC source

1-2 = grounded sink

Selects 24 VDC source control or grounded

sink control for digital inputs 0-3.

2-3 = 24 VDC source

1-2 = grounded sink

Factory set. Do not change

unless instructed to do so.

INTERFACE MODULE JUMPER SETTINGS

Default Setting

512K

1024K

RS-232C

*

**

Source

Source

Source

Source

2-3

2-3

Out

In

In

2-3

2-3

2-3

2-3

*

Inserting this jumper adds a 120 Ohm termination resistor across the RS-485 RX+ and

RX- lines.

** Inserting this jumper adds a 120 Ohm termination resistor across the CAN Bus.