LN-9400-00.9

- Automatic Mode with Analog Control (Dy-

namic Control)

If the GUN is configured as an automatic GUN

and external analog control of the flow rate is

being used, the setpoint value is only active if

there is no analog signal. Analog control is ac-

tive anytime that the input signal is greater than

0.25 VDC (4.63 ma).

- Automatic Mode with RIO Control

(Dynamic Control)

If the GUN is configured as an automatic GUN and

RIO control of the flow rate is being used, the set

point value has no meaning unless the RIO com-

manded set point is zero. In that case, the JOB

set point is used as the GUN flow rate set point.

Maximum Flow Rate

This parameter has 2 possible meanings, depen-

dent upon how the GUN is configured.

- Manual Gun

This parameter is an alarm set point. If the total

flow rate of the mixed material to the spray GUN

exceeds the amount specified by this parameter,

the GUN will shut OFF as the result of a FLOW

OUT OF RANGE FAULT.

- Automatic Gun

This parameter is used to scale the flow rate output

for the GUN's CHANNEL(s) to specify the desired

flow rate when a 10 VDC (or 20 ma) signal is ap-

plied to the analog set point input.

Minimum Flow Rate

This parameter has 2 possible meanings, depen-

dent upon how the GUN is configured.

When operating in 2K mode, this pa-

rameter relates to the total mixed material

delivered through the GUN.

NOTE

- Manual GUN

This parameter is an alarm set point. If the total

flow rate of the mixed material to the spray GUN

falls below the amount specified by this parameter,

the GUN will shut OFF as the result of a FLOW

OUT OF RANGE FAULT. If no alarm is desired,

set this parameter to zero (0) and the feature will

be disabled.

- Automatic GUN

This parameter is used to scale the flow rate

output for the GUN's CHANNEL(s) to specify the

desired flow rate when a 0 VDC (or 4.0ma) signal

is applied to the analog set point input.

Pot-Life Time

The time, in seconds, required for the mixed

material being used to set up or harden. This in-

formation is obtainable from the manufacturer of

the material. The controller will determine if any

mixed material is in the paint lines for longer than

the Pot-Life Time setting. It is recommended that

this time be somewhat less than the actual set up

time to allow time to clean the system in the event

that the Pot-Life timer expires. If the specified time

expires, a Pot-Life alarm is issued, warning the

operator that this problem exists. The Pot-Life

alarm

does not shut off the GUN, as this would

prevent the operator from triggering and expelling

the mixed fluid. The Pot-Life alarm status will re-

main until the expired material has been purged.

Pot-Life checking may be disabled by entering a

value of zero seconds. Since previous versions

of the DynaFlow firmware and software used the

value 999 minutes to disable Pot-Life checking,

the value of 999 seconds is not permitted and will

automatically be changed to zero seconds. When

upgrading DynaFlow firmware and software, JOBs

that specified any value other than 999 minutes

must be manually converted to seconds after

the upgrade is performed. A Pot-Life alarm may

be cleared by entering a Pot-Life Time of zero

seconds.

MVR High Pressure (Master and Slave)

This parameter allows the operator to limit the

maximum pressure that the transducer is allowed

to output to the fluid regulator in any mode.