LN-9400-00.9

Analog Hold mode without causing the fluid

tubes to pressurize to the material supply

pressure while the GUN is not triggered.

•

For systems with fast trigger cycles or where

dynamic control of fluid flow rates (different

flow rates during a JOB), mount the E/P

transducer as close to the material regulator

as possible. Remember that the transducers

MUST be mounted outside of the hazardous

location (refer to NFPA-70, NEC). For appli-

cations where the requested fluid flow is for

the most part consistent, and transitional re-

sponse time of the system is not as critical,

then the E/P transducers may be located in

the main control panel.

•

Be sure that stainless steel tubing or piping

and stainless steel fittings are used for all

fluid lines and connections where metal is

desired.

•

Always mount the flow meter and regula-

tor as close as feasible to the applicator. This

reduces paint line pulsation due to applicator

reciprocators and reduces the possibility of a

paint leak effecting paint delivered to the

part.

DynaFlow

TM

User Manual - Installation

26