Edit job (f4) – Ransburg DynaFlow User Manual User Manual

Page 38

Advertising
background image

LN-9400-00.9

Display Mode

This parameter has three possible values: RATIO

TOLERANCE, MIXED VOLUME, and POT LIFE. It

indicates what type of bar-graph will be displayed

on the main screen immediately to the left of the

flow rate bar-graph for each gun.

- Ratio Tolerance

This indicates the instantaneous ratio of the mate-

rial being fed into the static mix tube at any instant

in time.

- Mixed Volume

This indicates how much of the mixed volume

(the material between the static mix tube and the

applicator) has ratio material in it.

- Pot Life

This bar-graph indicates how old the oldest mixed

material is. (This is the material in the applicator.)

EDIT JOB (F4)

JOB parameters may be edited at any time. How-

ever, if a JOB is edited while active, the changes

made to CHANNEL related parameters will not

take effect until the GUN has been halted and

requested to be active again. Changes made to

GUN related parameters take effect immediately

after being saved to the Interface Module.

When a GUN is configured for two-component

operation and the Ratio is 99.0:1, or greater, the

GUN is said to be operating in pseudo single-

component mode. In this case, the slave (catalyst)

CHANNEL is NOT set to MVR LOW when the

GUN is placed in either Run or Load modes. How-

ever, if the slave (catalyst) CHANNEL is specified

as a clean CHANNEL, it will be turned on to MVR

HIGH in Clean mode.

When a 2K manual GUN is placed in single-com-

ponent operation, the master (resin) CHANNEL

simply turns on to the MVR HIGH output pressure

when the GUN is placed in Run mode. All fluid

flow is accounted for in the JOB totals.

When a 2K automatic GUN is placed in single-

component operation, the master (resin) CHAN-

NEL will control fluid per the set point parameter

in the JOB when the GUN is placed in Run mode

and a trigger signal is supplied. All fluid flow is

accounted for in the JOB totals.

Master Percentage

Refer to "Mix Ratio" information.

Slave Percentage

Refer to "Mix Ratio" information.

Flow Rate Set Point

This parameter has several functions depending

on the mode in which the GUN is configured.

- Manual Mode

If the GUN is configured as a manual GUN, this

value is the total desired flow rate (cc’s/min) when

the GUN is put in Load Mode (See "Load Mode"

in the "Operation" section of this manual).

- Automatic Mode without Analog Control

If the GUN is configured as an automatic GUN

and external analog control of the flow rate is not

being used, this is the total flow rate of the mixed

material desired at the spray GUN.

Any modifications to the JOB Param-

eters screen data are saved only when

the operator presses the "Store Data" key

(F5), otherwise the modifications will be

lost when the screen is exited with the es-

cape (ESC) key.

NOTE

34

Mix Ratio

Ratio is expressed as parts of Master CHANNEL

to parts of Slaved CHANNEL in the form of XX:1.

The Master CHANNEL is typically the resin and

the slave CHANNEL is typically the catalyst. If

the desired mix ratio is supplied as a percentage

of catalyst to the total volume. Use the Master

and Slave Percentage boxes instead.

Advertising