Messages, warnings and failures – Barco R9002240 User Manual

Page 49

Advertising
background image

Messages, warnings and failures

8-1

5975688 BARCOVISION 1609s 131097

8

MESSAGES, WARNINGS AND FAILURES

When selecting a new source,

information about this source will

be displayed on the screen. Source

number, horizontal and vertical fre-

quencies of the displayed source.

SOURCE 01

Announcement of the selected

source.

INPUT 01

Fh= 15.6 kHz

Fv= 050 Hz

enter

password

x x x x

Message to enter your password.

Password contains 4 digits.

text on

text off

These messages will be displayed

on the screen when pushing the

TEXT key.

Text ON : the 'bar scale indication'

will be enabled during the change

of an analog control in the 'opera-

tional mode' + all warnings and

failures will be displayed.

Text OFF : the 'bar scale indication'

will be disabled during the change

of an analog control in the 'opera-

tional mode' + all warnings and

failures will not be displayed.

PROJECTOR

ADDRESS :

003

Indication of the projector address

when activating the 'ADDRESS'

button on the RCU with a pencil or

other small object.

WARNING :

input not

available

When using the projector with the

RCVDS, this warning will be dis-

played when selecting an input

slot of an RCVDS where the input

board is missing.

WARNING :

source not

available

The input is a valid input but the

source is not connected to the

input terminals or the input source

is switched off.

WARNING :

invalid

key entry

When a wrong key is pressed on

the RCU.

WARNING :

end of ad-

just range

End of adjustment range.

WARNING :

input no

longer

available

Message will be displayed when

the input source is no longer avail-

able. The following message then

appears: 'check input signal or

select new source'.

WARNING :

input se-

lector not

available

It warns you to check the power

connection or the power status of

the RCVDS.

Next message will appear

immediatly on the screen : 'go to

stand-by'.

WARNING :

invalid

frequency

input

The entered frequency or applied

frequency of the source is out of

the projector's range.

table is

deleted

Message to inform that selected

table is deleted. This message will

be followed by 'confirm message',

on which the user has to answer.

FAILURE

I2C error

addr. : 7FH

Hardware failure. Call a qualified

service technician for repair.

FAILURE

short

circuit on

I2C bus

Hardware failure. Call a qualified

service technician for repair.

WARNING :

invalid

code entry

Message when the entered pass-

word is wrong.