3 installing the air locker – ARB RD153 User Manual

Page 19

Advertising
background image

3 Installing the Air Locker

17

IMPORTANT:

The seal housing must still be able to freely float after the tube

is connected to the bulkhead fitting. Therefore, it is critical to

ensure that the tube is not under any tension. To avoid this

always leave the tube long enough so that a hook shape can be

formed between the seal housing and the bulkhead.

NOTE : Use an automotive brake line tubing cutter to cut the

seal housing tube, never a hacksaw as this will leave
metal filings in the air system.

F

From the inside of the housing, insert the trimmed tube into the

bulkhead.

F

From the outside of the housing, assemble the small O-ring over

the top of the short length of seal housing tube protruding through
the bulkhead fitting.

F

While holding the seal housing tube into the bulkhead fitting, insert

the small drilled end of the center compression nut over the
extended tube as shown in the assembly diagram (Fig.10.), and
screw it into the bulkhead body, and lightly tighten.