Technical specifications, Features general information, Smartbox – L.B. White COMBO-MCS User Manual

Page 3

Advertising
background image

NEMA -4X

Dimensions ( L x W x H in.)

14 1/2 x 11 1/8 x 6

Inputs

120 /60 /1, 30 amps power required

Up to two 20k NTC temperature probes per zone

Two 25 amp 120 /60/1 relays for heater power

Outputs

F

Forced Air: 0-15 vdc control signal for the variable rate gas control valves; 500 mA.

Radiant: 24 VDC PWM Control Signal, 900 mA

Net weight (lbs.)

11.5

SmartBox

3

Technical Specifications

Enclosure

The SmartBox

maintains precise temperature thereby

reducing fuel consumption and improving animal
productivity and health. This configuration provides control
of both forced air and radiant heaters.

The SmartBox

interfaces to the room controller for

temperature control of the forced air heaters. The
SmartBox

operates the radiant heaters independent

of the room controller

Operator interface touch pad.

-- Sets manual operation
-- Allows setting the clock at initial set-up
-- Activates and operates sensors
-- Provides for installing and changing the

temperature management curve.

Handles up to 10 temperature set points with up to

225 days per period.
-- Linearly ramps from one set point temperature

to the next over the duration days for that
period

Separate temperature control zones

-- Up to four temperature sensors for forced air

heaters.

-- One separate sensor for radiant heaters
-- Zone 1 can handle two forced air heaters
-- Zone 2 interfaces with a proportional zone control

for either spark or manual ignition heaters.

-- Maximum capacity: 24, I-17 LP/NG

radiant heaters.

-- Zone control #s: Manual ignition 28564

Spark Ignition 28580

Heat Enable

-- Used with Zone 1 (forced air heaters) only.

-- Connected to the room controller in a

manner to allow operation only when the
room controller determines a need for
heat.

-- Minimizes interference between

the heating and ventilation
systems.

Indicator Lights

-- Heat Zone On: Green Light
-- Sensor Failure: Red Light

a. Identifies sensor malfunction.
b. If one sensor fails in a zone controlled by

two sensors, the remaining sensor allows

continued operation.

-- Cycle Complete: Amber Light

Control Reset Switch

-- Allows the producer to reset the controller back to

day 1 for the start of a new cycle.

-- Position the switch to OFF and then to ON to

reset.

This manual will instruct you in the installation and
operation of the SmartBox

. Have a qualified installer

review this manual with you so that you fully understand
the controller and how it functions.

When calling for technical service assistance, or for other
specific information, always have the model number and
serial number available.

Contact your local L. B. White distributor or the L. B. White
Co., Inc. for assistance, or if you have any questions about
the use of this product or its application.

The L. B. White Co., Inc. has a policy of continuous product
improvement. It reserves the right to change specifications
and design without notice.

Features

General Information

Advertising