Component Identification, Part Number, and Function

4

Control Reset Switch (570456)
Powers up the SmartBox

for heating zone and allows the

producer to reset the control back to day 1 for start of new
cycle. Position from On to Off, then back to On.

Fuses
Used for protection of the programmable controller and the
variable rate gas control valves.

Fuse for Forced Air heaters: 572812
Fuse for Incoming Power and Radiant Brooders: 572918

Fuse Holders
Secures the fuse into position within the electrical circuit.

Fuse holder with 1/4 in. male tabs:572809
Fuse holder with 3/16 male tabs: 572808

Indicator Lights

Green: (26392) Indicates which heat zone is in operation
Amber: ( 572813) Indicates heat cycle complete
Red: (571333) SmartBox

temperature sensor failure

Programmable Controller (572917)
Micro-processor used for the operation of the SmartBox

system and operation of the signal conditioners.

Relays (572811)
Used for sending of power to the heaters in a specific heat
zone.

Sensor (572815) Not Illustrated
Used for monitoring temperature within the confinement
space. Interfaces to the programmable controller to allow
operation of the Smart Sensevariable rate gas control
valves.

Signal Conditioners
Used to process the electrical signal from the programmable
controller for operation of the variable rate gas control
valves.
Forced Air Heaters : 572771
Radiant Brooders : 572913

Touch Pad / Display (572914)
Used for set up of the SmartBox

for system operation :

temperature , heating days, etc

Transformers

Used for reducing incoming 115 VAC to 24

VAC for powering of programmable controller and signal
conditioners.
Radiant Brooders (UPPER): 572912
Forced Air Heaters (LOWER): 570230

PROGRAMMABLE
CONTROLLER

FUSES

RELAYS

TRANSFORMERS

TOUCH PAD
AND DISPLAY

FIG. 1

FIG. 2

RADIANT FORCED AIR

SIGNAL CONDITIONERS