Sensor location, Fig. 5 – L.B. White COMBO-MCS User Manual

Page 6

Advertising
background image

Sensor Location

Each SmartBox

controls two zones of heat.:

-- Zone 1: Two forced air heaters

One SmartBox

sensor may be used for each zone of

heat. However two or more sensors are used for
optimum temperature management.

-- Zone 2: Radiant heaters

Use only the L.B.White SmartBox

sensors provided

with the SmartBox

, or order replacements as

needed. Do not use sensors from other controller
s ys t ems a s t hese a re not com p a ti b l e wi th t he
L.B.White SmartBox

.

See below for proper SmartBox

sensor location.

6

GUARDIAN

w/ SMARTSENSE™

ZONE1
ZONE2

CYCLE
SENSOR

RESET

ROOM CONTROLLER

FAN(S)

SmartBoxSYSTEM DIAGRAM

FORCED AIR AND RADIANT HEATERS

SmartBox

GUARDIAN WITH

Smart Sense

120 VAC

POWER SUPPLY

120 VAC

POWER SUPPLY

120 VAC TO SPARK IGNITION

INFRACONICS ONLY (ZONE 2)

CONTROL SIGNAL TO ZONE PANEL VARIABLE RATE
SOLENOID VALVE (USE MINIMUM 18 GAUGE WIRING))

GUARDIAN WITH

Smart Sense

ENABLE

USE 18 GAUGE WIRE FROM THE
SmartBox
TO EACH TEMPERATURE SENSOR
LOCATION. UP TO 4-FORCED AIR AND
1 RADIANT ZONE

RADIANT SENSOR

ZONE PANEL

ROOM CONTROL SENSORS

SmartBoxSENSOR(S) LOCATED WITHIN 6 IN. OF

EXISTING ROOM SENSOR AND AT SAME HEIGHT

SmartBoxSENSOR(S) LOCATED WITHIN 6 IN. OF

EXISTING ROOM SENSOR AND AT SAME HEIGHT

FIG. 5

Advertising