Interconnection – L.B. White COMBO-MCS User Manual

Page 7

Advertising
background image

A

All wiring must be done by a qualified electrician in
accordance with local, state, and national electrical
codes.

Unlatch the control box cover, and open the control
panel.

Select locations on either the side or the bottom where
a wiring access holes may be drilled. Do not drill holes
at the top of the control box.

Install the appropriate sized water tight connectors.

Use customer supplied minimum 18 gauge conductor
and the appropriate wiring terminals for connecting the
Smart Box

to the heater’s variable gas control valve,

to the room controller contacts, and the temperature
sensors.

Re fe r to t h e fo l l ow i n g i n s t r u c t i o n s fo r w i r i n g
c o n n e c t i o n s . Re fe r to t h e w h i te f l a g s o n t h e
SmartBox

leads for interconnections.

Connecting the 120 VAC Power Supply to the SmartBox

.

Connect to hot, neutral, and ground leads as shown in
Fig.6.

FIG. 6

Connecting 120 VAC Power to the Heaters

Connect leads in SmartBox

to heating Zones 1 and 2.

See Fig.7.

FIG. 7

Wiring from SmartBox

to the forced air heater’s Smart

Sense

variable rate gas control valve

a. Connect the Smart Sense™ gas control valve wiring

for Zone 1 at the brown SmartBox

leads as

shown in Fig.8.

FIG. 8

b. Route the wiring from these leads through the

gas inlet hole at the heater’s case. See Fig.9.

c. Attach 1/4 in. insulated female terminals to

these wires and connect to either terminal on
the valve. See Fig. 9.

FIG. 9

d.

See Fig.10 for typical connections. Each SmartBox

zone can control two heaters.

FIG. 10

7

Interconnection

ROUTE WIRING
THROUGH HOLE

CONNECT WIRING TO TERMINALS
( NOT POLARITY SENSITIVE)

WARNING

Electrical Shock Hazard

Disconnect the electrical supply before installation of

the SmartBox

.

Failure to follow this warning may result in personal
injury or death.

USED FOR SPARK IGNITION

RADIANT HEATERS ONLY. DO
NOT USE FOR MANUAL IGNITION
RADIANT HEATERS

FORCED AIR

WIRING FROM

Smart Box™

To FORCED AIR

Smart Sense™

VARIABLE RATE GAS CONTROL VALVE

VOL

TS T

O V

AL

VE

VA

LV

E

HEATER 1
GAS VALVE

HEATER 2
GAS VALVE

Advertising