C

Connecting the building controller’s heating contacts to the
SmartBox

(for contact closure) for Zone 1 forced air heaters.

(Zone 2 is for radiant heaters and operates independent of
the room controller. This does not require contact closure
wiring)

Connect to the red leads as shown in Fig.11. These are
not powered contacts.
-- Remove the wiring from the heat contacts (one for

each zone) in the room controller.

-- Connect these same contacts to the SmartBox

Enable wiring Zone 1, and to common Zone 1.

- This allows each SmartBox

zone

to operate within the temperature
parameters of the room controller.

FIG. 11

Wiring from SmartBox

to the radiant heaters.

The SmartBox

operates the variable rate proportional

solenoid control used for the radiant heaters, and
operates independent from the room controller.

Separate installation and operation instructions
accompany the appropriate control for manual igntion
or spark ignition radiant heaters.

See Fig.12 for connection of the SmartBox

to the

proportional control valve for radiant heaters. Fig13
identifies the proportional valve and Fig.14 illustrates a
typical connection from the SmartBox

to the valve.

FIG. 12

FIG. 13

FIG. 14

Connecting the SmartBox

temperature sensors

(Zone 1 has 4 sensors, Zone 2 has 1 sensor)

Connect 18 gauge (minimum) wiring between the gray
leads as shown in Fig.14 and the SmartBoxsensor.
See page 6 for sensor location.

Solder the connection between the SmartBox

sensor

and the conductor. Wrap this connection with electrical
tape.

Use only t he L.B.Whit e SmartBox

sensors, part

number 572815, provided with the SmartBox

, or

order replacements as needed. Do not use sensors
from room controllers as these are not compatible with
the L.B.White SmartBox

.

FIG. 14

8

BLUE

BLUE

COMBO SmartBox

PROPORTIONAL CONTROL VALVE
CONNECTOR BLOCK

+

-

2

1

GROUND