Error

Cause

Action

E01

Clamping motor power too low or bad electric
wiring

Call service

E02

Preset minimal clamping pressure not reached

Call service

E03

Door opened during mixing or door switch
defective

Keep door closed during mixing. If persistent,
call service

E04 - E06

SK550 Mainboard 5V or 12V circuitry overload

Call service

E07

Clamping plate reached minimal position

Place (taller) can

E08

Can shrunk during mixing

Use less fragile can

E09

Component overload

Call service

E10

No pulses received from encoder

Call service

E12

T5 (turbo FET) of 100V power supply
defective

Call service

E18

Clamping plate risen or loosened during
mixing

Check can position

E20 - E33

SK550 Mainboard component overheat (> 90°
Celsius)

Pause for cooling, check machine ventilation.
If persistent, call service

E41

EEPROM read error

Allow reset to default settings. If persistent,
call service

E71

SK550 Mainboard defective (T7 of T10)

Call service

E89

SK550 Mainboard defective (T8 of T9)

Call service

E99

Shake motor or wiring short circuit

Call service

E100

SK550 Mainboard defective (main motor
power feed)

Call service

E101

Power supply from wall socket too high

Check mains. If persistent, call service

E102

Power supply from wall socket too low

Check mains. If persistent, call service