Lull 944E-42 Service Manual User Manual

Page 397

Advertising
background image

8.145

Model 644E-42/944E-42

Rev. 6/04

Hydraulic System

NOTE:

When checking pressures in

circuits, refer to Section 8.7,

“Hydraulic System Testing,” for

correct pressure readings.

If the auxiliary hydraulic

connection can’t connect

Not

OK

Push the auxiliary hydraulic

pressure release switch.

If OK

Refer to Section 9.14.5,

“Auxiliary Hydraulic Pressure

Release Switch 644E-42,

Not

OK

Check auxiliary hydraulic

pressure release valve.

NOTE:

Before pressure checking

circuits, refer to Section 9.8.29,

“Dual Joystick - Auxiliary

Hydraulic Circuit &

Troubleshooting,” to ensure the

electrical circuits for the pilot

select valve are functioning

properly.

Replace the release valve.

If the auxiliary hydraulic

connection can’t connect

or disconnect.

Before troubleshooting any
hydraulic circuit, ALWAYS
begin by checking the
following:

1. Hydraulic oil level in the

reservoir

2. All hoses, tubes, fittings

for leaks, kinks,
interference, etc.

3. Air in the lines

Advertising