Commissioning 7 – Lukas LH 2/ 1,8-70 DIN User Manual

Page 12

Advertising
background image

12

NOTE:

With the LUKAS hand pump, a little idle stroke may occur when the unit is first

used in the high pressure range.

However, this idle stroke independently stops after a device is operated

2-3 times.

7.1 Unlocking the pump

Unlock (1.) the shipping lock of the pump by

sliding the locking pin in the direction of the

hand wheel until it comes against the stop.

To lock (2.) the pin, move it until it comes

against the stop in the other direction. To do

this, the lever must be in the home position

(at the tank).

Locking pin

ATTENTION!

The hand pump should be as close to horizontal as possible, because otherwise

the usable amount changes!

The oil fill plug must always be unscrewed one turn before starting operation of

the hand pump! This enables the aeration and bleeding of the hydraulic tank.

After the work is completed but before transport, the oil fill plug should be

retightened!

Commissioning

7.

7.2 Retracting the handle

You can pull out the handle by applying pressure to both sides of the thrust piece and

simultaneously pulling in the direction of the handle end until the thrust piece re-engages.

1.

2.

1.

2.

7.3 Bleeding the pump

1. Open the discharge valve.

2. Open the oil fill screw plug on the tank container and check the oil fill level. The oil fill

level should come up to approximately 1-2 cm below the top edge of the oil reservoir.

3. In this state, work the pump handle several times.

Hand wheel

Advertising