9

5.2 Adapter blocks

Adapter block

Function/use

Connection plate

with fittings

Possibility of connecting hose

lines directly to the hand

pump

Connection

plate with quick-

disconnect-couplings

Possibility of connecting hose

lines directly to the hand

pump via quick-disconnect-

couplings

Connection plate

with monocouplings

Possibility of connecting hose

lines directly to the hand

pump via monocoupling

Connection options for rescue equipment

6.

ATTENTION!

Make sure to store all plugs, screw plugs and/or dust caps in a way that

prevents them from getting dirty or lost.

After completion of the work, seal off all lines using screw plugs and/or dust

caps to prevent contamination of the hand pump.

When connecting lines to the hand pump, we recommend positioning it

vertically so that the ports point upward. This reduces the danger of hydraulic

fluid escaping.

6.1 Fittings

The hose lines are connected via fittings to the hydraulic pump.

1.

2.

1. First remove the closure caps from

the fittings.

2. Then, you can connect the hose lines

to the fittings and tighten them with a

tightening torque of M

A

= 40 Nm.

ATTENTION!

The return hose must always be connected at the "T" port of the

connection block.

The supply hose line must instead be connected at the "P" port.