Lukas LH 2/ 1,8-70 DIN User Manual

Page 18

Advertising
background image

18

E F

G

H

Tank

J

K

L

3. Remove the nut (item E) and sealing ring situated under it (item F).

4. Remove base plate (item G) and the sealing ring (item H).

5. Remove tank and the seal (item J) as well as the connection plate (item K) and seal

(item L).

6. The assembly is done in reverse order. Replace all damaged parts with new ones.

The tightening torque of the nuts is 40 Nm.

10.5.3 Lever replacement

The lever must be replaced if external damage is present that represents a danger for user

and device upon further use.

Procedure:

1. Drive out dowel pin (item M).

M

N

2. Remove lever (item N) and replace with a new one.

3. Reinsert dowel pin (item M).

10.5.4 Couplings

WARNING / CAUTION / ATTENTION!

Couplings should not be repaired; they should be replaced with original LUKAS

parts!

10.5.4.1 Monocouplings

The monocouplings must be replaced if:

- exterior damage is present,

- the lock does not function,

- in the coupled and/or decoupled state, hydraulic fluid continuously escapes.

Advertising