Lukas LH 2/ 1,8-70 DIN User Manual

Page 21

Advertising
background image

21

Device does not move

back into the starting

position, moves

incompletely back toward

the starting position or

moves more slowly into

the starting position than

normal.

Discharge valve closed

Open discharge valve.

Fluid level in the hydraulic

tank too high

Reduce hydraulic fluid

down to max. fill level.

Loose hydraulic coupling

Check all couplings and

retighten them.

Enclosed air in the system Bleed pump as described

in the chapter “Bleeding

the pump”.

Line length too long

Use shorter lines.
Use hydraulic fluid with

a different, more suitable

viscosity.

Defect on the device

Heed the specifications

of the separate operating

instructions of the

device.

Connected device not

reaching its limit position

Fluid level in the hydraulic

tank too low

Add hydraulic fluid up to

max. fill level.

Attention: move the

device back into the

base position before

adding fluid!

Usable hydraulic fluid

quantity of the pump is

insufficient

Use a different device with

a usable quantity below

the maximum usable

quantity of the pump.

Connected rescue device

does not achieve its

power-related performance

data

Max. permissible operating

pressure of the pump is

not reached

Replace pressure

control valve or have

it recalibrated by an

authorised dealer or

directly by LUKAS.

Fluid leaks on the

hydraulic fluid tank

(especially at the refill tap)

Due to return flow of the

hydraulic fluid from the

device, the maximum fill

quantity of the tank is

exceeded

Reduce hydraulic fluid

down to max. fill level.

Seals defective

Replace seal.

Hydraulic fluid with milky

cloudiness

Water or condensation

water in the system

Perform hydraulic fluid

change immediately.

Problem

Cause

Remedy