Transport 9, Maintenance and repair 10 – Lukas LH 2/ 1,8-70 DIN User Manual

Page 14

Advertising
background image

14

Transport

9.

8.2 Shutdown / storage

To shut down or store the pump, seal all hydraulic connections with the associated screw

plugs or dust caps.

After sealing the hydraulic ports, open the drain screw (not up to the stop!) to depressurise

the pump.

Then carefully clean the external dirt off of the hand pump.

In addition, with a longer storage time, the outside of the device should be cleaned and all

visible mechanical moving parts need to be oiled.

ATTENTION!

After completion of the work but before transport, check to make sure the oil fill

screw plug is screwed in tightly!

Make sure the pump is not stored in a damp environment.

The pump lever is used as a carrying handle! Special pumps may be the exception in this

case. These pumps are custom-assembled for each customer; therefore, there may be a

different transport device or none! In these cases, please refer to your authorised dealers

or LUKAS directly. The lever must be locked for transport, as described in the chapter

"Unlocking the pump".

Maintenance and repair

10.

Service work may only be performed by the device manufacturer or by personnel trained by

the device manufacturer and authorised LUKAS dealers.

All components must be replaced with original LUKAS spare parts, which are listed in the

spare parts list, because in this context even required special tools, assembly instructions,

safety aspects and/or checks absolutely must be taken into consideration.

During the assembly work, pay particular attention to the cleanliness of all components

because dirt can damage the equipment!

10.1 Basic requirements

WARNING / CAUTION / ATTENTION!

To perform maintenance and repairs, personal safety equipment appropriate for

the work is an absolute requirement. (incl. shields).

Assembly and repair work on the pump may only be performed if the entire

hydraulic system is

depressurised!

Couplings should not be repaired; they should be replaced with original LUKAS

parts!

NOTE:

Always send the warranty tab back to LUKAS hydraulics GmbH.

You should always contact LUKAS or an authorised dealer before using outside

couplings.

Do not perform any repairs without the corresponding LUKAS spare parts list,

because necessary tightening torques for screw connections and/or in some

cases also important additional information are listed there.

Advertising