Danger – Snorkel TB47J User Manual

Page 33

Advertising
background image

Chapter 7 – Prestart Inspection

TB47J – 0075182

29

A

Danger

The aerial platform can tip over if it becomes un-

stable. Death or serious injury will result from a tip-

over accident. Do not operate the aerial platform if

a tire is leaking air or is in poor condition where a

blow out could occur.

Test the air pressure with a pressure gauge to make sure

the tires are properly inflated. Check the tires several

times throughout the day to see that they are properly

inflated.

Foam Filled

Inspect for large holes or cuts where foam is coming out

of the tire. Look for large imbedded objects, such as angle

iron, that can rip a tire open.

Punctures caused by bolts, screws, or nails are not a

problem for foam filled tires.

Lower Control Station

With no personnel in the platform, test the operation of

each control from the lower controls (refer to Figure 7.11).

Figure 7.11 – Lower Controls

Operating Controls

Use the following procedure to operate the machine from

the lower controls.

1. Turn the battery disconnect switch on.

2. At the lower controls, pull the emergency stop but-

ton outward and place the control selector switch in

the ground position.

3. Insert the key into the master switch and turn the

switch to start until the engine starts, then release.

4. Let the engine warm to operating temperature.

5. Hold the ground operation switch upward.

A

Danger

Pinch points may exist between moving compo-

nents. Death or serious injury will result from be-

coming trapped between components, buildings,

structures, or other obstacles. Make sure all person-

nel stand clear of the aerial platform while perform-

ing the prestart inspection.

6. Test the operation of each function in both directions.

Note

When checking the turntable rotation function in the

clockwise direction, the turntable will rotate toward you.

Emergency Stop

Push the emergency stop button in to turn off the engine.

The lower control functions should not operate with the

emergency stop in this position.

Emergency Power

Place the battery disconnect switch, the emergency stop

button, and the master switch in the on position.

Hold the engine/emergency power switch in the emer-

gency power position and the ground operation switch in

the on position to operate the aerial platform from the

lower controls using the emergency power system.

Emergency Lowering

The main boom can be lowered in an emergency using

the emergency lowering knob. The emergency lowering

knob is at the base of the main boom lift cylinder (refer to

Figure 7.12).

Use the following procedure to test the emergency lower-

ing system.

1. Use the lower controls to raise the main boom.

Emergency
Stop Button

Control Selector

Switch

Ground Operation

Switch

Start Switch

Emergency

Power Switch

Advertising