Chapter 11 – Troubleshooting

TB47J – 0075182

59

Symptom

Circuit breaker will not reset.

Electrical outlet does not work.

Improper AC generator output

voltage.

Hydraulic fluid temperature 200°F

(93°C) or more.

Severe hydraulic leak.

Possible Cause

Electrical circuit has not had time to

cool.

Electrical system malfunction.

Power supply not plugged in.

GFCI is tripped.

Machine/generator switch not in the

generator position.

Power cord to platform is not plugged

into the AC generator.

Hydraulic oil is cold and thick.

Prolonged boom operation or driving.

High pressure fluid return to reser-

voir caused by kinked or twisted

hose.

Hydraulic system component failure.

Failure of hose, tube, fitting, seal,

etc.

Corrective Action

Wait a minute or two for circuit to

cool, then push circuit breaker but-

ton in to reset.

Do not operate machine until repairs

are made.

Plug a source of power into the

power-input connector on the wiring

box.

Push reset button on outlet.

With engine running, place the ma-

chine/generator switch in the genera-

tor position.

Plug power cord into the outlet on the

left side of the wiring box.

Use cold weather hydraulic oil as rec-

ommended for weather conditions.

Warm oil before operating the ma-

chine.

Stop operation until fluid cools.

Remove the kink or twist from the

hose. Let fluid cool before resuming

operation.

Stow the machine and do not oper-

ate until repairs are made.

Do not operate machine until repairs

are made.