Chapter 8 – Operation

42

TB47J – 0075182

Use cold weather hydraulic oil as recommended in the

machine General Specifications in temperatures of 10°F

(0°C) or below.

Preparing for Operation

Use the following procedure to prepare the aerial platform

for operation.

1. Perform a prestart inspection as described in Chap-

ter 7.

2. Place the battery disconnect switch in the on posi-

tion.

3. Close and latch the doors.

4. Before painting or sandblasting make sure the sand-

blast protection kit and the platform control cover are

properly installed. These options, when used prop-

erly will protect the control placards and cylinder rods

from paint overspray and abrasion while sandblast-

ing.

Lower Controls

The lower controls override the upper controls. This means

that the lower controls can always be used to operate

the platform regardless of the position of the upper con-

trol emergency stop button.

Boom, turntable, and platform functions may be oper-

ated from the lower controls. The lower controls may be

used for initial set up of the aerial platform, and for testing

and inspection.

Use the following procedure to operate boom, turntable,

or platform functions using the lower controls. Refer to

Figure 8.2.

1. On dual fuel machines, set the fuel switch to either

LPG or gasoline.

2. Open the shut-off valve on the tank if using LPG.

3. Pull the emergency stop button (refer to Figure 8.2)

outward and place the control selector switch in the

ground position.

4. Turn the start switch to on and pause a few seconds

while the alarm sounds to alert others that the ma-

chine is about to start. Turn the switch to start, then

release it to on. The engine will not start if the switch

is left in the on position for 30 seconds or longer

before turning it to start. The switch must be turned

back to off before the engine will start.

5. Let the engine warm to operating temperature.

6. Hold the ground operation switch up while operating

the control toggle switches.

Figure 8.2 – Lower Controls

7. Hold the appropriate toggle switch in the desired di-

rection.

8. Release the function toggle switch to stop movement.

9. Place the ground operation switch in the off position

when no functions are being operated.

Upper Controls

The upper controls may be used for driving the aerial plat-

form and positioning the booms and platform while on the

job.

Use the following procedure to operate machine func-

tions using the upper controls.

1. At the lower controls, pull the emergency stop but-

ton outward and turn the start switch to on. Place

the control selector switch in the platform position.

2. On dual fuel machines, set the fuel switch to either

LPG or gasoline.

3. Open the shut-off valve on the tank if using LPG.

4. Enter the platform and securely close the gate.

5. Attach the fall restraint lanyard to one of the anchor

points.

Emergency

Power Switch

Ground Operation

Switch

Start Switch

Emergency
Stop Button

Control Selector

Switch

Advertising