Chapter 11 – Troubleshooting

TB47J – 0075182

57

Symptom

Engine will not start from upper

controls.

Engine dies when the control se-

lector switch at the lower controls

is placed in the platform position.

Constant tone alarm sounds while

the engine is running.

Constant tone alarm sounds and

engine shuts off.

All functions stop working.

Lower controls do

not work.

Possible Cause

The main system circuit breaker on

the upper control panel or wiring box

has tripped. The engine will not crank.

Upper controls are not set-up prop-

erly.

High engine temperature.

Low oil pressure.

No alternator current/broken fan belt.

High engine temperature.

Low oil pressure.

Low fluid level in reservoir.

Engine or pump failure.

Circuit breaker is tripped.

Electrical system malfunction.

Battery disconnect switch turned off.

Emergency stop switch at lower con-

trols is pushed in to the off position.

Corrective Action

Push the main system circuit breaker

button back in. If the button pops back

out, refer the problem to a qualified

service technician.

At the upper controls, pull the emer-

gency stop button upward and turn

the anti-restart master switch on.

Lower the platform and reduce the

engine speed to idle for five minutes.

Turn the engine off and let it cool. Do

not restart the engine until the cause

of overheating has been corrected.

Lower the platform and turn the en-

gine off. Do not restart the engine until

the cause of low oil pressure has been

corrected.

Turn the engine off. Do not restart the

engine until the cause of no alterna-

tor current has been corrected or the

fan belt is replaced.

Let the engine cool. Do not restart

the engine until the cause of overheat-

ing has been corrected.

Do not restart the engine until the

cause of low oil pressure has been

corrected. The engine can be re-

started with low oil pressure, but it

will only run a few seconds before it

shuts off again.

Check fluid level. Add correct type of

fluid if necessary.

Manually stow the machine using the

emergency power system or the

emergency lowering knob.

Push circuit breaker button in to re-

set.

Manually lower the boom using the

emergency lowering knob.

Place switch in the on position.

Pull the emergency stop button out

to the on position.

Advertising