background image

Chapter 11 – Troubleshooting

56

TB47J – 0075182

Symptom

Engine will not start from lower

controls.

Engine will not start from upper

controls.

Possible Cause

Switches are set wrong. The engine

will not crank.

The start switch was left in the on po-

sition for 30 seconds or longer before

turning it to start.

The main system circuit breaker on

the wiring box has tripped. The en-

gine will not crank.

Switches are set wrong. The engine

will not crank.

Platform foot switch is activated.

The start switch was left in the on

position for 30 seconds or longer be-

fore turning it to start.

Corrective Action

Turn the battery disconnect switch on

and then at the lower controls:

• Turn the master start switch off.

• Pull the emergency stop button

outward.

• Place the control selector switch

in the ground position.

• Place the start switch in the on

position for 5 seconds and then

turn the switch to start.

Turn the start switch back to off, then

to start within 30 seconds.

Push the main system circuit breaker

button back in. If the button pops back

out, refer the problem to a qualified

service technician.

Turn the battery disconnect switch on

and then at the lower controls:

• Turn the start switch off.

• Pull the emergency stop button

outward.

• Place the control selector switch

in the platform position.

• Place the start switch in the on

position.

From the upper controls:

• Turn the start switch off.

• Pull the emergency stop button

outward.

• Place the start switch in the on

position for 5 seconds and the

then turn the switch to start.

Do not step on foot switch while start-

ing the engine.

Turn the start switch back to off, then

to start within 30 seconds.