Chapter 8 – Operation

TB47J – 0075182

45

3. Place the fuel switch in the LPG position.

To switch from LPG to gasoline with the engine running:

1. Place the fuel switch in the gasoline position.

2. Close the shut-off valve on the LPG tank.

Air Line

The optional air line may be used to conduct air for tool

operation at the platform. The input connector is at the

rear of the chassis and the output connector is at the

platform on the rotator guard. The maximum working pres-

sure of the line is 250 psi (1,723 kPa).

The air line may be used to conduct fluids such as water

or antifreeze. Contact Snorkel for compatibility informa-

tion before using the air line to conduct other fluids.

A

Caution

Fluid in the air line can damage some air tools or

freeze and damage the line. Drain and blow out the

air line after using it to conduct fluids.

Use the following procedure to drain the air line.

1. Close the input connector on the chassis.

2. Open the output connector at the platform.

3. Raise the boom slightly above horizontal.

4. Open the input connector on the chassis.

5. Allow the fluid to drain from the line.

6. Lower the boom and close both connections.

Driving Lights

The optional driving lights are for use in dimly lit areas

and are not intended for driving on public roadways. There

are two headlights at the front of the chassis and two

blinking taillights at the rear of the chassis.

The lights are operational when the battery disconnect

switch and the master switch are turned on.

Note

Working with the driving or platform work lights on, while

the engine is off, can discharge the batteries enough

that the engine will not start or the emergency power sys-

tem will not operate. If the engine cannot be left running

while the lights are on, start and run the engine for at

least 15 minutes each hour.

Platform Work Lights

The optional platform work lights are located on the top

rail of the platform. The direction a light points can be

adjusted by using two

1

/

2

″ wrenches to loosen the clamp

below the light.

Figure 8.5 – Wiring Box

A

Caution

Cold hydraulic oil does not flow well and may pro-

duce improper generator output voltage. Improper

outlet voltage can damage some electrical power

tools and equipment. Warm the hydraulic oil be-

fore operating the generator.

Do not operate the generator unless the hydraulic oil tem-

perature is at least 100°F (38°C). Refer to Cold Weather

Start-Up for a hydraulic oil warm-up procedure.

Use the following procedure to supply power to the elec-

trical power outlet if the machine is equipped with the

optional generator.

1. Plug the generator cord into the outlet on the left

side of the wiring box.

2. Start the engine and place the machine/generator

selector switch, on the front of the upper control, panel

in the generator position.

The engine will run at high idle while the generator is

operating. The generator will continue to operate as long

as the engine is running and the switch is in the genera-

tor position.

Dual Fuel

The dual fuel switch is located on the front of the lower

control panel.

Before starting the engine, place the fuel switch in the

gasoline or the LPG position. Open the shut-off valve on

the LPG gas tank if using LPG. Always keep the LPG

tank shut-off valve closed when not using LPG.

To switch from gasoline to LPG with the engine running:

1. Open the shut-off valve on the LPG tank.

2. Place the fuel switch in the off position until the en-

gine starts to die.

Power-Input

Connector

Advertising