27

032007

active. For the user this means that it is possible to set a speed
in the Off operating mode that will be required for continuous
operation or for several agitation processes in timed mode.

NOTE: After the power has failed, the set time is erased and the
device switches into Offline operating mode (standstill). The set
speed stays adjusted.

Control model

The target
speed and
upper speed
limit (max.
800 rpm) re-
quired for the
agitation pro-
cess can be set
with the aid of
the left turn
button and are
shown on the
right display.
Continuous
mode is activa-
ted by presing the left turn but-
ton. If a target time is set in the right display in continuous mode
or is saved from previous agitation processes, the agitation pro-
cess can be continued in continuous mode by pressing the right
turn button. The agitation process can be terminated by pressing
the left or the right turn button.

ATTENTION! After a power failure, the device will not
automatically start up in operating mode A or B by its-
elf. In operating mode C, the device automatically starts
up by itself.

After the power failed, the set time (timed mode or continuous
mode) is erased and the device switches into Offline operating
mode (standstill).

Control mode

The amount
of time requi-
red for the agi-
tation process
can be adjusted
with aid of the
right turn but-
ton and is
shown on the
right display.
If a target time
(max. 9h
59min) is set
in the right dis-
play or has
been saved from previous
agitation processes, you can activate or terminate the agitation
process with the left turn button while setting the target speed.
You can exit timed mode and interrupt the agitation process by
pressing on the right turn button.

ATTENTION! After a power failure, the device will not
automatically start up in operating mode A or B by its-
elf. In operating mode C, the device automatically starts
up by itself.

Basic model

You can adjusted the speed (max. 800 rpm) by turning the left
turn button. When you do this, you should note that the agitator
does not begin to run until continuous mode or time mode is

345

345

I

min

/

PV

PV

min

n

i

959

.

959

:

345

345

I

min

/

PV

PV

min

n

i

959

:

345

I

min

/

PV

PV

min

n

i

959

:

Time mode in mode of operation A

Continuos mode in mode of operation A

Display after power failure

in mode of operation A

Setting the speed

345

345

I

min

/

PV

PV

min

n

i

959

.

959

:

345

345

I

min

/

PV

PV

min

n

i

959

:

345

I

min

/

PV

PV

min

n

i

959

:

Time mode in mode of operation A

Continuos mode in mode of operation A

Display after power failure

in mode of operation A