Prior to use inspection, Inspecting cable tension and slip indicator – JLG 740AJ Operator Manual User Manual

Page 38

Advertising
background image

SECTION 2 - USER RESPONSIBILITIES, MACHINE PREPARATION, AND INSPECTION

2-18

– JLG Lift –

3121295

be given to the arresting distance of the deployed shock
absorbing lanyard compared to the proximity of lower levels, or
the ground, in the event of a fall.

IF THE FALL ARREST SYSTEM IS USED TO ARREST A FALL OR IS OTH-
ERWISE DAMAGED, THE ENTIRE SYSTEM MUST BE REPLACED AND
THE PLATFORM FULLY INSPECTED. REFER TO THE SERVICE MANUAL.

Prior to Use Inspection

Fall arrest systems must be inspected prior to each use.
Replace if there are any signs of wear or damage to any of the
components.

Prior to use inspection should include a visual inspection of
the following items:

Cable: Proper tension, broken strands, corrosion.
Fittings: Loose fittings and fractures, damage to
hanger
Transfastener: Damage, free and proper sliding
Attaching Hardware: Loose, missing, properly
tightened

Inspecting Cable Tension and Slip Indicator

Cable tension is adjusted by using the Line Tenser. The Line
Tenser is the disc at the end of the cable (shown below).
When proper tension is achieved, the disc will spin by hand.
When less than proper tension is present the disc will not
turn by hand. The cable will stretch normally over time. In
order to tension the cable the turnbuckle can be tightened.
Rotate the turnbuckle until the proper tension is achieved.

Advertising