Torque Requirements

Hydraulic Oil

NOTE:

Hydraulic oils must have anti-wear qualities at least to API
Service Classification GL-3, and sufficient chemical stabil-
ity for mobile hydraulic system service. JLG Industries
recommends Mobilfluid 424 hydraulic oil, which has an
SAE viscosity index of 152.

NOTE:

When temperatures remain below 20° F (-7° C), JLG
Industries recommends the use of Mobil DTE 13M.

Table 6-13. Torque Requirements

Description

Torque Value (Dry)

Interval

Hours

Bearing To Chassis

See Note

50/600*

Bearing To Turntable

See Note

50/600*

Wire Rope

15 ft. lbs (20 Nm)

150

Wheel Lugs

See Section 6.4

150

Engine Mounting Bolts

165 ft. lbs. (231 Nm)

A/R

Engine Manifold Mounting Bolts

30 ft. lbs. (42 Nm)

A/R

*Check swing bearing bolts for security after first 50 hours of operation and
every 600 hours thereafter. (See Swing Bearing in Section 3.)

Table 6-14. Hydraulic Oil Specifications

HYDRAULIC SYSTEM OPERATING

TEMPERATURE RANGE

SAE VISCOSITY

GRADE

+0° to +180° F (-18° C to +83° C)

10W

+0° F to +210° F (-18° C to +99° C)

10W-20, 10W-30

+50° F to +210° F (+10° C to +210° C)

20W-20