SECTION 6 - GENERAL SPECIFICATIONS & OPERATOR MAINTENANCE

3121204

– JLG Lift –

6-25

4. Wheel Drive Hub

Lube Point(s) - Level/Fill Plug
Capacity - 17 oz. (1/2 Full)
Lube - EPGL
Interval - Check level every 3 months or 150 hrs of oper-

ation; change every 2 years or 1200 hours of operation

5. Hydraulic Return Filter

Interval - Change after first 50 hrs. and every 6 months

or 300 hrs. thereafter or as indicated by Condition Indi-
cator.