SECTION 2 - USER RESPONSIBILITIES, MACHINE PREPARATION, AND INSPECTION

2-6

– JLG Lift –

3121204

TO AVOID COLLISION AND INJURY IF PLATFORM DOES NOT STOP
WHEN A CONTROL SWITCH OR LEVER IS RELEASED, REMOVE FOOT
FROM FOOTSWITCH OR USE EMERGENCY STOP TO STOP THE
MACHINE.

1. Check hydraulic boom sequence cam valves. Raise,

extend, retract and lower tower boom. Check for smooth
and proper operation.

NOTE:

Perform checks from ground controls first, then from plat-
form controls.

2. Operate machine from ground control.

3. Move TOWER TELESCOPE to ‘out’ position. Tower

should not telescope with TOWER BOOM less than fully
elevated ‘up’. (Must be approximately 13 degrees from
vertical to move TOWER TELESCOPE ‘out’.)

4. Move TOWER BOOM to ‘up’ position and hold until the

TOWER BOOM is completely elevated. Move TOWER
TELESCOPE to ‘out’ position and hold until the TOWER
BOOM is fully extended.

5. With TOWER BOOM completely extended, place

TOWER LIFT in ‘down’ position. Tower boom should not
LIFT ‘down’ unless the TOWER BOOM is fully retracted.

6. Place TOWER TELESCOPE to ‘in’ position and fully

retract the TOWER BOOM. Place TOWER BOOM to
‘down’ and fully lower the TOWER BOOM. Upright in
vertical position. If Tower Boom does not rest on stop
with machine in the stowed position, this indicates
upright is out of plumb. See Section 4, Boom Synchro-
nizing Procedure, in Service Manual.

TO AVOID TIPPING OVER DO NOT USE MACHINE IF TOWER BOOM
SWITCHING IS OUT OF SEQUENCE.

NOTE:

For adjustments see Service Manual - Limit Switch Adjust-
ments.

7. Check elevation limit switch as follows:

Main Boom Angle Limit Switch.

a. Lift boom up to 5 degrees above horizontal. Limit

switch should activate at this point.

b. Lift main boom down until limit switch resets. This

should be 4 degrees to 9 degrees below horizontal.

NOTE:

Angle indicator should be placed between the main boom
pivot pin and the main boom lift cylinder attach point on
the base boom. On machines not equipped with ADE, the
main boom angle limit switch activation may be checked

Advertising