JLG 600A_AJ Operator Manual User Manual

Page 29

Advertising
background image

SECTION 2 - USER RESPONSIBILITIES, MACHINE PREPARATION, AND INSPECTION

3121204

– JLG Lift –

2-7

by using test light in terminal # 24 in the main terminal
box. Tower angle switch must be reset before main boom
angle switch can be activated.

Tower Boom Angle Limit Switch.

a. Place machine on level surface.

b. Using the bottom of the upright and the ground as a

reference, lift the tower boom 40" to 42" (101.6 to
106.6 cm) from the stowed position. The tower
boom angle limit switch should activate at this
point.

c. Lower the tower boom 25" to 30" (63.5 to 76.2 cm)

from where the switch activated. This switch should
reset at this point.

NOTE:

On machines not equipped with ADE, the tower boom
angle limit switch activation may be checked by using a
test light in terminal #43 on the main terminal box.

NOTE:

Step 8 is only applicable for 600A ANSI market machines.

8. Check capacity limit switch as follows:

Main Boom Length Switch.

a. Lift main boom to approximately horizontal.

b. Telescope boom out until 500 lb. (227 kg for ANSI

markets and 230 kg for CE and Australia markets)
light comes on (may need to used auxiliary power
to position boom correctly).

c. Mark the wear pad location on the main fly boom.

d. Telescope the main boom to full extension.

e. Measure from the mark on the fly boom to the wear

pad. The dimension should be 125" to 127" (317.5
to 322.6 cm).

Main Boom Angle Switch.

a. Lift main boom to approximately horizontal.

b. Telescope boom out until 500 lb. (227 kg for ANSI

markets and 230 kg for CE and Australia markets)
light comes on (may need to used auxiliary power
to position boom correctly).

c. Lift main boom up until 1000 lb. (454 kg for ANSI

markets and 450 kg for CE and Australia markets)
light comes on. The boom angle at this point should
be 55 degrees to 60 degrees.

d. Lift main boom down until 500 lb. (227 kg for ANSI

markets and 230 kg for CE and Australia markets)
light comes on. The boom angle at this point should
be 45 degrees to 50 degrees.