8-7

G10-55A, G12-55A

Hydraulic System

a. Pressure Specifications

Before S/N 0160037877

G10-55A - Before S/N 0160031864
G12-55A - Before S/N 0160030644

G10-55A - S/N 0160031864 & After
G12-55A - S/N 0160030644 & After

Hydraulic Circuit

Test Port

Function Used to

Test

Adjustment

Location

Pressure Range

Main

P1 (A)

Bottom Tilt Down

1

3600-3650 psi

(248-252 Bar)

Pilot

JS1 (B)

No Function

2

500-550 psi

(34-38 Bar)

Standby

P1 (A)

No Function

3

750-775 psi

(52-53 Bar)

Service Brake

Supply

BV1 (C)

Bottom Steering,

Any Mode

4

1000-1100 psi

(69-76 Bar)

Steering

GLS (D)

Bottom Steering,

Any Mode

5

2400-2500 psi

(165-172 Bar)

Lift

LS2 (E)

Bottom Lift Down

6

3500-3525 psi

(241-243 Bar)

Boom Retract

LS2 (E)

Bottom Boom

Retract

7

3050-3075 psi

(210-212 Bar)