DESCRIPTION

Plasma Cutter

The Plasma Cutter will be capable of cutting up to a thickness of 3/8 in.
metal. This cutter will be capable of producing 27A at 92 VDC @ 35% duty
cycle or 14A at 92 VDC @ 60% duty cycle.

Generator Output

ANSI Specs:240V;60Hz; 3-Phase; 7.5kW and 240V/120V:60Hz; Single
Phase:6kW.

CE Specs: 400V; 50Hz; 3-Phase; 7.5kW and 220V; 50Hz; Single Phase;6kW.

Engine Speed of 1800 rpm +/- 10%.

ACCESSORY RATINGS

Table 1. - Plasma Cutter Characteristics - P/N’s-4530024 and 4530025

Spec.

Rated Out-

put

115 V

(+/- 15%)

230 V

(+/- 15%)

115 V

KVA/KW

230 V

KVA/KW

Plasma

Gas

Plasma Gas

Flow/Pres-

sure

Rated Cut-

ting Capac-

ity @ 10 IPM

Max.

OCV

ANSI

P/N

4530024

Amperes Input @

Rated Output, 60 Hz,

Single-Phase

27 A @ 92

VDC @ 35%

Duty Cycle

28 max;

0.33*

14 max;

0.13*

3.32 KVA

3.25 KW

3.25 KVA

3.19 KW

Air or

Nitrogen

Only

4.5 CFM

(129 L/Min)

@ 60 PSI

(414 kpa)

3/8 in.

(10 mm)

288 VDC

14 A @ 92

VDC @ 60%

Duty Cycle

17 max;

0.30*

8.4 max;

0.13*

CE

P/N

4530025

Amperes Input @

Rated Output, 50 Hz,

Single-Phase

27 A @ 92

VDC @ 35%

Duty Cycle

27 max;

0.33*

13 max;

0.13*

3.11 KVA

3.09 KW

3.04 KVA

3.04 KW

Air or

Nitrogen

Only

4.5 CFM

(129 L/Min)

@ 60 PSI

(414 kpa)

3/8 in.

(10 mm)

288 VDC

14 A @ 92

VDC @ 60%

Duty Cycle

16 max;

0.33*

7.8 max;

0.17*

*While Idling.

Table 2. - Plasma Cutter Characteristics - P/N-1001098012

Spec.

Rated Output

Amperes

Input @ Rated

Output, 60 Hz,

Single-Phase

KVA/KW

Plasma Gas

Plasma Gas

Flow/Pressure

Rated Cutting

Capacity

@ 10 IPM

Max. OCV

120 Volts

±10%

(20A)

27 A @ 91 VDC

@ 20% Duty

Cycle

28.8 max;

0.30*

3.4 KVA

3.2 KW

Air or Nitrogen Only

@ 90 - 120 PSI

(621 - 827 kPa)

4.5 CFM

(129 L/Min)

@ 60 PSI

(414 kpa)

3/8 in.

(10 mm)

400 VDC

120 Volts

±10%

(15A)

20 A @ 88 VDC

@ 35% Duty

Cycle

20.6 max;

0.30*

2.5 KVA

2.3 KW

240 Volts

±10%

(27A)

27 A @ 91 VDC

@ 35% Duty

Cycle

13.9 max;

0.13*

3.3 KVA

3.0 KW

* While idling.