SECTION 2 - SKYPOWER™ (BELT DRIVEN)

2-2

– JLG Accessory Manual –

3124242

DESCRIPTION

This belt-driven generator supplies AC power to the platform to run tools,
lights, cutting and welding equipment through an AC receptacle. All power
regulation components are located in a watertight box that is connected by
cable to the generator. The generator supplies power when running at the
specified speed with the power switch on (switch is located on platform). A
three-pole, 30 Amp circuit breaker protects the generator from overload.

Generator Output

ANSI Specs:

240V;60Hz; 3-Phase; 7.5kW and 240V/120V:60Hz; Single Phase:6kW.

CE Specs:

3-phase, 240-volt, 7.5kw, 18.3-amps, 1.0-pf

1-phase, 240 volt, 6.0kw, 26-amps, 1.0-pf

1-phase, 120 volt, 6.0kw, 50-amps, 1.0-pf

Peak:

3-phase 8.5kw

1-phase 6.0kw

ACCESSORY RATINGS

SAFETY PRECAUTIONS

General

READ AND UNDERSTAND THE OPERATORS MANUAL FOR THE SPECIFIC JLG MODEL
BEING USED.

DO NOT OVER LOAD PLATFORM.

1. Make sure no personnel are beneath platform.

2. This factory installed option is available only on models specified.

3. Keep lanyard attached at all times.

4. Do not use electrical tools in extremely wet conditions.

5. Use correct voltage for tool being used.

6. Do not over load circuit.

Model

Drive -Type

Generator Speed

18RS/24RS/400S/450A

Series II

450AJ Series II/460SJ

510AJ/600A/600AJ

600S/600SC/600SJ

660SJ/660SJC

800A/800AJ/800S

860SJ/1100SJP/1200SJP

1250AJP/1350SJP/1500SJP

Belt-Drive/Pulley

3000rpm (50 Hz)

3600 rpm (60 Hz)